E013
ABB Grid Frequency Out of Range

Charger shows E013 and stops charging shortly after start; may coincide with grid disturbances.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Supply frequency outside allowed range (e.g., not 50/60 Hz), Generator or inverter-based supply instability, Faulty frequency sensing circuit on control board

How to Fix / Troubleshooting

Note: ABB chargers monitor grid frequency to ensure stable operation.

  • Check supply source: If the charger is powered from a generator or inverter, verify that it provides a stable 50/60 Hz output within ABB’s specified tolerance.
  • Measure frequency: Use a multimeter with frequency measurement to confirm the actual line frequency at the charger input.
  • Test on utility power: If possible, temporarily connect the charger to a standard utility-fed circuit to see if E013 disappears.
  • Control board diagnosis: If frequency is within spec but E013 persists, the frequency sensing circuit on the control board may be defective and require board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board