E015
ABB
Firmware / Software Exception
Charger shows E015 and the display or LEDs may be frozen; no charging possible.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted firmware image, Incomplete firmware update, Internal software crash, Faulty microcontroller on control board
How to Fix / Troubleshooting
Note: Software faults can often be resolved without hardware replacement.
- Hard reboot: Turn off the upstream breaker for at least 60 seconds, then restore power and observe if the charger boots normally.
- Check update history: If E015 appeared after a firmware update, use the ABB app or service tool to verify update status and reapply the update if necessary.
- Factory reset: Perform a factory reset from the user interface or app, then reconfigure essential parameters.
- Offline update (technician): A technician may use an ABB service dongle or USB/serial interface to reload firmware directly to the control board.
- Replace control board: If the microcontroller or flash memory is damaged and cannot hold firmware reliably, replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.