E019
ABB Line-to-Line Voltage Imbalance / Phase Error (for multi-phase capable units)

Charger shows E019 and the charging session is terminated; may coincide with grid voltage imbalance.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect phase wiring at input terminal block, One phase missing or low, Loose connection on one line conductor, Faulty voltage sensing on one phase

How to Fix / Troubleshooting

Applies to: ABB home chargers that support 3‑phase or multi-phase operation.

  • Verify wiring: With power off, confirm that L1, L2, L3 (if used), neutral, and earth are connected to the correct terminals as per ABB wiring diagram.
  • Measure each phase: With power on (electrician only), measure voltage between each phase and neutral, and between phases. Values should be within the specified range and relatively balanced.
  • Tighten terminals: De-energize and tighten all phase terminals on the input block to the specified torque.
  • Check upstream supply: Ensure the supply panel is providing all phases correctly and that no breaker has tripped.
  • Board diagnosis: If supply is correct but E019 persists, the phase voltage sensing circuit on the control board may be faulty and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Input Terminal Block / Main Control Board