ABL
Nuisance Tripping / Upstream Protection Trip
ABL charger trips the upstream RCD or breaker as soon as charging starts, but no specific error code is shown on the charger.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Upstream RCD not compatible with EV chargers (e.g., Type AC instead of Type A or B), Combined leakage from multiple circuits, Inrush current exceeding breaker characteristics, Internal leakage or fault in ABL charger
How to Fix / Troubleshooting
Steps:
- Confirm that the upstream RCD type meets ABL and EV charging requirements (typically Type A with DC detection in charger, or Type B).
- Test the charger on a dedicated circuit if currently shared with other loads.
- Have an electrician measure leakage currents and verify breaker characteristics (C or D curve as recommended).
- If trips occur even with correct protection and dedicated circuit, internal leakage or fault must be investigated by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
ABL RCD/RCM module