Possible Causes
Tripped upstream breaker or RCD, Blown internal fuse on ABL power board, Loose supply wiring at input terminals, Failed auxiliary power supply on main board
How to Fix / Troubleshooting
Safety: Treat the circuit as live until proven otherwise.
Steps:
- Check the upstream breaker and RCD; reset if tripped and observe if they trip again.
- Verify that other devices on the same circuit (if any) have power.
- With power OFF, open the ABL charger and check that the supply conductors are firmly connected and that any internal fuses are intact (replace only with identical rated fuses).
- If supply and fuses are good but the unit remains dead, the internal auxiliary power supply or main control board is likely defective and must be replaced by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
ABL auxiliary power supply module
Check Price on Amazon