ABL charger shows E10; charging is disabled and the unit may reboot repeatedly.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Turn OFF the upstream breaker before opening the charger.
Checks:
- Observe behavior: If the display or LEDs flicker or the unit reboots, suspect low‑voltage instability.
- Disconnect accessories: If possible, disconnect optional modules (e.g., external load management, external meter interface) one at a time to see if E10 clears.
- Inspect connectors: Ensure all low‑voltage connectors between the power board, main control board, and communication/RFID boards are fully seated.
Technician actions: Measure the low‑voltage rails (e.g., 5 V, 12 V) on the main board according to ABL service documentation. If out of tolerance, replace the main control board or the separate auxiliary power supply module if fitted.
Repair Difficulty
Required Part