ABL charger shows E18; charging is disabled and the unit may indicate a DC residual current sensor error.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: The DC residual current sensor is a critical safety component. Do not bypass it.
Steps:
- Turn OFF power and open the charger.
- Locate the DC sensor: Typically a ring‑type sensor through which the phase and neutral conductors pass.
- Check connector: Ensure the sensor cable is securely connected to the main control board.
- Inspect routing: Verify that only the intended conductors pass through the sensor and that no additional cables are routed too close, which could cause interference.
Repair: Replace the DC residual current sensor assembly if defective. If E18 persists, the sensor interface on the main control board may require board replacement.