ABL
No Charge Start Without Visible Error
Vehicle plugged in but charging does not start; no error code shown, LEDs remain steady or show ‘ready’ state.
Advertisements
Possible Causes
EV’s charging timer or schedule active, Maximum current on ABL charger set too low, Access control (RFID/app) not completed, Control pilot not reaching EV due to minor contact issue
How to Fix / Troubleshooting
User checks:
- Check vehicle settings: Ensure no delayed charging schedule is active in the EV. Set the car to ‘charge immediately’ and retry.
- Authenticate if required: If your ABL charger uses RFID or app authorization, present a valid card or start the session in the app.
- Verify current limit: In the ABL app or via DIP switches, confirm that the maximum current is not set below the EV’s minimum requirement (often 6–8 A).
- Reconnect plug: Unplug and firmly reinsert the Type 2 connector until it clicks. Wait 30–60 seconds to see if charging starts.
If the charger remains in ‘ready’ state with multiple vehicles and cables, have an installer check the control pilot circuit and configuration.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements