E017
Alfen PEN Conductor Fault Detection

E017 displayed; charger indicates PEN (combined neutral‑earth) fault on TN‑C‑S system and disables charging.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Voltage rise on earth due to broken PEN in supply, Incorrect earthing configuration in charger settings, Faulty PEN monitoring circuit, Loose neutral/earth link in upstream installation

How to Fix / Troubleshooting

Safety first: A PEN fault is extremely hazardous. Do not attempt to bypass PEN detection. Immediately stop using the charger until the supply is checked.

  • Step 1 – Stop using the charger: Leave the charger switched off at the breaker.
  • Step 2 – Check other circuits: Look for unusual behavior in other circuits (tingling from metalwork, fluctuating lights). If present, contact your DNO/utility urgently.
  • Step 3 – Verify configuration: A qualified installer should confirm that the charger’s earthing mode is correctly set for the site’s earthing system.
  • Step 4 – Inspect neutral/earth connections: An electrician should check the main earth bar, neutral bar, and any PEN fault devices for loose or damaged conductors.
  • Step 5 – Test PEN detection: If the supply is confirmed healthy, but E017 persists, the PEN detection circuit in the charger may be faulty.
  • When to call a technician: Always involve a licensed electrician and, if needed, the network operator. Charger PCB replacement may be required.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

PEN Fault Detection Circuit on Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements