E13
Amperfied
Dynamic Load Management / Current Sensor Fault
Charger shows E13 and limits or stops charging when multiple loads are active in the house.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty external current transformer (CT) clamp, Incorrect CT orientation or wiring, Loose CT connection to load management input, Defective load management controller on main board
How to Fix / Troubleshooting
Safety: CT clamps are usually installed on live mains conductors; only an electrician should adjust them.
- Check configuration: In the Amperfied app or web interface, verify that dynamic load management is configured correctly (main fuse size, phases, etc.).
- Inspect CT cabling (visually): Ensure the small signal cable from the CT clamp to the charger is not damaged or pulled out.
- Have an electrician verify CT installation: The CT must be clamped around the correct conductor(s) with the arrow pointing in the proper direction. The electrician should correct orientation and tighten connections.
- If CT and wiring are correct: The load management input circuit on the main control board may be faulty and require board replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
External CT Clamp / Load Management Input Circuit
Check Price on Amazon