E15
Amperfied Internal Energy Meter / MID Meter Fault

Charger shows E15 and refuses to start; often described as ‘meter error’ on smart metered models.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective internal kWh meter module, Loose meter communication cable, Firmware mismatch between meter and main board, Meter power supply failure

How to Fix / Troubleshooting

Note: On some models, charging is blocked if the internal meter is not functioning.

  • Power‑cycle: Turn off the charger at the breaker for 5 minutes, then restore power and check if E15 clears.
  • Check backend/app: Ensure that the charger’s firmware is up to date and that any required meter initialization has been completed.
  • Technician inspection: A technician should open the unit, verify that the internal meter module is powered, reseat its communication cable, and check for error LEDs on the meter (if present).
  • Replace meter module: If the meter is non‑responsive or fails self‑tests, it must be replaced with the correct Amperfied‑approved MID meter module.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Internal Energy Meter Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements