AMPROAD
Mechanical Vibration / Loose Mounting
Charger enclosure vibrates noticeably or rattles when charging at high current.
Advertisements
Possible Causes
Loose wall mounting hardware, Vibrating internal transformer or inductor, Cable strain pulling on enclosure, Resonance between charger and mounting surface
How to Fix / Troubleshooting
Safety: Turn OFF power before tightening any mounting hardware or opening the unit.
- 1. Check wall mount:
- Verify that all mounting screws and brackets securing the AMPROAD charger to the wall are tight.
- Ensure the wall anchors are appropriate for the wall material.
- 2. Inspect internal components:
- With power OFF, open the charger and check that large components (transformer, inductor, contactor) are firmly secured.
- 3. Cable management:
- Ensure the output cable is supported and not pulling on the enclosure, which can cause vibration.
- 4. Add damping (if needed):
- Use manufacturer-approved rubber washers or spacers on mounting points to reduce resonance.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
AMPROAD Wall Mounting Bracket / Internal Mounts
Check Price on Amazon