Possible Causes

Loose wall mounting hardware, Vibrating internal transformer or inductor, Cable strain pulling on enclosure, Resonance between charger and mounting surface

How to Fix / Troubleshooting

Safety: Turn OFF power before tightening any mounting hardware or opening the unit.

  • 1. Check wall mount:
    • Verify that all mounting screws and brackets securing the AMPROAD charger to the wall are tight.
    • Ensure the wall anchors are appropriate for the wall material.
  • 2. Inspect internal components:
    • With power OFF, open the charger and check that large components (transformer, inductor, contactor) are firmly secured.
  • 3. Cable management:
    • Ensure the output cable is supported and not pulling on the enclosure, which can cause vibration.
  • 4. Add damping (if needed):
    • Use manufacturer-approved rubber washers or spacers on mounting points to reduce resonance.