Load Management Not Limiting Current
Charger does not follow configured load management; house main breaker trips when EV and other loads run together.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
External CT clamp not installed or installed on wrong conductor, Load management disabled or misconfigured in Andersen app, Faulty CT input on main control PCB, Incorrect main fuse rating set in configuration
How to Fix / Troubleshooting
Safety first: If your main breaker trips, reduce EV charging current or stop charging until load management is working correctly.
User steps:
- Open the Andersen app and verify that load management is enabled and that the correct main fuse rating is set.
- Temporarily reduce the maximum charge current to a safe level that does not trip the main breaker.
For an electrician:
- Confirm that the CT clamp is installed on the correct mains tail and oriented properly.
- Check CT wiring continuity to the Andersen CT input.
- Test the CT input on the main control PCB and replace the PCB if it does not read CT current correctly.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
External CT Clamp / Main Control PCB