Audi Cooling Control / Fan Stuck On

Audi EV charger’s internal fan runs at full speed constantly, even when not charging.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted fan driver transistor on main board, Faulty temperature sensor reading high, Firmware bug keeping fan command active, Stuck relay controlling fan power

How to Fix / Troubleshooting

Safety first: Continuous fan operation is not immediately dangerous but indicates a control issue.

  • Power-cycle the charger: Turn off the breaker for a few minutes, then restore power. Observe whether the fan stops after boot.
  • Check temperature readings: In the service or installer interface (if available), view internal temperature sensor values. If they read abnormally high at room temperature, the sensor or its wiring is faulty.
  • Inspect fan wiring: With power off, ensure the fan is connected only to its designated header and not accidentally shorted to a constant supply.
  • Replace faulty components: If the sensor is defective, replace the temperature sensor harness. If the driver circuit is shorted, replace the main control board.

Leaving the fan running constantly may shorten its life; correct the underlying control fault.