E008
Autel Contactor / Relay Failure

Charger displays E008; charging cannot start and the contactor does not engage.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Welded or stuck contactor contacts, Open contactor coil, Loose control wiring from main board to contactor, Faulty contactor driver circuit on main board

How to Fix / Troubleshooting

Safety first: The contactor switches high current. Only qualified persons should service it.

  • Listen for click: When starting a charge, you should hear a distinct click from the internal contactor. No click suggests a coil or control issue; repeated clicking with no charge suggests contact problems.
  • Visual inspection: With power off and cover removed, inspect the contactor for discoloration, melted plastic, or signs of overheating.
  • Check coil connections: Verify the low-voltage control wires from the main control board to the contactor coil are secure and undamaged.
  • Measure coil resistance: Using a multimeter (qualified only), measure the contactor coil resistance and compare to specifications. An open or shorted coil requires contactor replacement.
  • Replace contactor if needed: If contacts are welded or the coil is defective, replace the contactor with an Autel-approved part. If the contactor tests good but E008 persists, the driver circuit on the main board may be faulty and the board should be replaced.
Advertisements

Repair Difficulty

Professional Required 5/5