E016
Autel Control Pilot Signal Out of Range

Charger shows E016; display may indicate 'CP Fault' or 'Control Pilot Error'.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted CP to ground, Open CP resistor network in vehicle or charger, Damaged CP wire in cable, Faulty CP driver on main board

How to Fix / Troubleshooting

Safety first: Turn off power before inspecting wiring.

  • Inspect connector: Check the pilot pin in the connector for damage, contamination, or corrosion. Clean gently if needed.
  • Check cable integrity: Look for visible damage along the cable. If the cable has been run over or sharply bent, the CP conductor may be broken or shorted.
  • Test with another vehicle: Try charging a different EV. If E016 only occurs with one vehicle, the vehicle’s inlet or CP resistor network may be faulty.
  • Internal CP wiring: With power off, verify the CP wire is securely connected to the main control board and not pinched or cut.
  • Board diagnosis: If wiring and cable are good, the CP driver or sensing circuit on the main board may be defective and the board should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Autel EVSE Type 2 Charging Cable Assembly
Check Price on Amazon