Besenergy No AC Input / Dead Unit

Charger has no power at all; display is blank and no LEDs are lit even though the breaker is ON.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped or faulty circuit breaker, Loose line connections at breaker or charger, Blown internal input fuse, Failed internal low-voltage power supply

How to Fix / Troubleshooting

Safety first: Turn OFF the breaker before touching any wiring. Verify with a non-contact tester.

  • 1. Check the breaker: Ensure the dedicated breaker feeding the Besenergy charger is fully in the ON position. Reset if tripped. If it trips again immediately, stop and call an electrician.
  • 2. Verify supply voltage (electrician): Have a licensed electrician measure voltage at the charger input terminals. If no voltage is present, the issue is upstream (panel, breaker, wiring).
  • 3. Inspect internal fuses (qualified): With power OFF and cover removed, locate any internal fuses on the input or low-voltage power supply board. Test and replace blown fuses with identical ratings only after confirming the cause of failure.
  • 4. Check input wiring: Confirm that L1, L2, and ground are securely connected and show no signs of overheating or looseness.
  • 5. Replace low-voltage power supply: If AC is present at the input but the display remains dead and internal fuses are good, the low-voltage power supply module is likely failed and should be replaced.

When to call a professional: Any work involving live circuits or internal components should be done by a licensed electrician or EVSE technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Low-Voltage Power Supply Module