E18
Blink Charge Session Control / Timeout Fault

Blink EV charger displays E18 and may indicate a time-out or session control error.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Firmware bug in session management, Intermittent pilot signal causing repeated restarts, Network authorization delays on managed units, Faulty real-time clock or memory on main board

How to Fix / Troubleshooting

Safety first: No internal work should be done live. Turn off power before opening the unit.

Steps to troubleshoot:

  • Reboot charger: Power cycle at the breaker and attempt a new session.
  • Check cable and connector: Ensure the J1772 handle seats firmly in the vehicle and that the latch engages fully. A loose connection can cause pilot interruptions.
  • Network latency: For networked Blink chargers, verify that the internet connection is stable and not heavily congested.
  • Firmware update: Apply any available firmware updates from Blink that address session stability.

If E18 continues across multiple vehicles and after firmware updates, the main control board may have a hardware fault in its timing or memory circuits and should be replaced.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Blink Main Control Board
Check Price on Amazon