BYD
No AC Supply / Internal Power Supply Failure
Charger has no power at all; display is off and LEDs are dark even when breaker is on.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped upstream breaker or RCD, Loose supply wiring at BYD charger input, Blown internal fuse on control power supply, Failed low-voltage power supply module on main PCB
How to Fix / Troubleshooting
Safety first: Work on supply wiring only with power off and by a qualified person.
- Check upstream protection: Verify the dedicated breaker and any RCD feeding the BYD charger are in the ON position and not tripped.
- Test another load: If possible, have an electrician temporarily connect a test lamp or meter at the charger input to confirm voltage is present.
- Inspect input terminals: With power off, check that line, neutral, and earth are securely clamped in the charger’s input block.
- Look for internal fuse: A technician can open the unit and check any internal fuses on the control power supply; replace only with identical ratings.
- If supply is good but still dead: The internal low-voltage power supply or main control PCB is likely faulty and must be replaced.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Low-Voltage Power Supply Module
Check Price on Amazon
We may earn a commission from links on this page.