E15
BYD Dynamic Load Management / CT Sensor Fault

Charger displays E15 and charging is limited or disabled; may show a message about load management or current limit.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted current transformer (CT) on main supply, CT installed backwards or on wrong conductor, Loose CT wiring to BYD charger, Faulty load management module on main PCB

How to Fix / Troubleshooting

Safety first: CTs are installed on live mains; only an electrician should handle them. Turn off power before any work.

  • Check app configuration: Ensure dynamic load management is enabled only if CTs are installed and configured correctly in the BYD app.
  • Inspect CT installation: An electrician should verify that the CT is clamped around the correct conductor and oriented according to the arrow marking.
  • Check CT wiring: Confirm that CT leads are firmly connected to the BYD charger’s CT input terminals and not swapped.
  • Test without load management: Temporarily disable load management in settings (if allowed) to see if charging resumes normally.
  • Replace CT or module: If wiring and configuration are correct but E15 persists, replace the CT sensor or load management module.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Current Transformer (CT) Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements