Chevrolet Nuisance Tripping / Overcurrent or Ground Fault on Circuit

Charger trips the house breaker or GFCI outlet as soon as charging starts.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Undersized or long branch circuit wiring, Shared circuit with other loads, Ground fault in charger cable, Incompatible GFCI breaker with built-in charger GFCI

How to Fix / Troubleshooting

Safety first: Repeated breaker trips indicate a potential hazard. Do not keep resetting without investigation.

  • Step 1 – Confirm dedicated circuit: Ensure the Chevrolet home charger is on its own dedicated breaker with no other loads.
  • Step 2 – Check breaker type: If using a GFCI breaker with a charger that already has internal GFCI/CCID, consult the installation manual; a standard breaker may be recommended instead.
  • Step 3 – Inspect cable and charger: Look for visible damage, moisture, or burning on the cable and charger enclosure.
  • Step 4 – Lower current setting: Temporarily reduce the charger’s maximum current and see if the breaker still trips. If not, the circuit may be undersized or too long.
  • Step 5 – Electrician evaluation: Have an electrician verify wire gauge, breaker size, and insulation resistance of the circuit and charger.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Branch Circuit Breaker and Wiring
Check Price on Amazon

We may earn a commission from links on this page.