Enel X Nuisance Tripping of Upstream Protection

Charger trips the household breaker or RCD/GFCI whenever a charging session starts.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Charger leakage current near RCD threshold, Shared RCD with other loads, Incorrect breaker type or rating, Internal ground fault or insulation issue

How to Fix / Troubleshooting

Safety: Repeated tripping indicates a potential fault. Do not repeatedly reset without investigation.

  • Step 1 – Verify breaker type: Confirm that the breaker and RCD type and rating match Enel X installation requirements (e.g., Type A or B RCD, correct amperage).
  • Step 2 – Dedicated circuit: Ensure the charger is on a dedicated circuit, not shared with other large loads.
  • Step 3 – Visual inspection: Check the charger cable and enclosure for signs of moisture or damage.
  • Step 4 – Insulation test (electrician): Have an electrician perform insulation resistance tests on the charger circuit and cable.
  • Resolution: If the charger is confirmed to be the cause, replace the charge cable assembly or main control board depending on where leakage is found.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Charge Cable and Connector Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements