Enel X
Cooling Fan Overrun / Noise
Charger’s internal fan runs loudly or continuously, even at low load or when idle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Clogged fan or vents, Worn fan bearings, Faulty temperature sensor reading high, Firmware fan control issue
How to Fix / Troubleshooting
Safety: Turn OFF power before touching internal components.
- Step 1 – Clean vents: Remove dust and debris from external vents with a dry cloth or vacuum.
- Step 2 – Internal cleaning: With power OFF, open the unit and gently clean the fan blades and surrounding area.
- Step 3 – Sensor check: Ensure the temperature sensor is properly attached to the heat sink and not hanging loose.
- Step 4 – Firmware update: Update firmware to ensure correct fan control logic.
- Resolution: Replace a noisy or worn internal cooling fan. If the fan still runs unnecessarily, the temperature sensor or main control board may be misreading temperature.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Internal Cooling Fan
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements