E04
Enel X
Protective Earth (PE) Loss or High Impedance Ground
Charger displays E04 and will not energize; app may indicate ‘ground missing’ or ‘protective earth fault’.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open ground conductor in supply wiring, Loose ground terminal inside charger, Corroded or undersized ground connection, Faulty ground sensing circuit on control board
How to Fix / Troubleshooting
Critical safety warning: A missing or poor ground is dangerous. Do not attempt to bypass ground detection. Turn OFF power at the breaker and do not use the charger until the issue is resolved.
- Step 1 – Visual supply check: With power OFF, remove the charger cover and inspect the incoming ground (PE) conductor at the terminal block. Ensure it is securely clamped and not corroded.
- Step 2 – Tighten terminals: Using an insulated screwdriver, gently tighten the ground terminal screw and verify the line and neutral terminals are also secure.
- Step 3 – Panel/bonding check: Have a qualified electrician verify that the service panel ground and bonding are correct and that the circuit feeding the Enel X charger has a continuous ground back to the panel.
- Step 4 – Test with meter (electrician): Measure continuity between the charger ground terminal and the main panel ground bar. High resistance or open circuit indicates a wiring issue.
- Step 5 – Control board check: If wiring and ground are confirmed good, the internal ground sensing circuit on the main control board may be defective and require replacement.