E28
Enel X Configuration / Parameter Corruption

Charger displays E28 and refuses to start; app may show ‘configuration error’ or ‘parameter set invalid’.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted configuration memory, Incomplete firmware update, Invalid current or voltage settings, EEPROM failure on control board

How to Fix / Troubleshooting

Safety: Incorrect configuration can cause unsafe operation; do not override limits without understanding circuit ratings.

  • Step 1 – Verify settings: In the Enel X app, check that maximum current, supply type, and protection settings match the installation.
  • Step 2 – Factory reset: Perform a factory reset from the app or front panel, then re‑enter all configuration parameters carefully.
  • Step 3 – Firmware reflash: If available, reinstall the latest firmware to restore default parameter structures.
  • Resolution: If E28 persists after reset and reconfiguration, the configuration memory (EEPROM) on the main control board may be defective and the board should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements