Possible Causes
Faulty internal current sensor calibration, Incorrect CT orientation (for external CTs), Firmware bug in energy calculation, Timekeeping errors affecting kWh aggregation
How to Fix / Troubleshooting
Note: This affects reporting and billing, not basic charging.
- Compare over time: Check discrepancies over several sessions to rule out one-off anomalies.
- Verify CT installation: For systems using external CTs, have an electrician confirm correct orientation and placement.
- Firmware update: Ensure the charger is running the latest firmware, which may include metering fixes.
- Factory reset (if acceptable): Reset configuration and re-onboard the charger to clear corrupted data.
- If still inaccurate: The internal metering IC or CTs may be out of tolerance and require board or sensor replacement.