EO Charging Overcurrent / Short Circuit on Supply

EO charger trips the upstream MCB or main breaker during charging.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Configured current limit higher than breaker rating, Short circuit in contactor or wiring, Internal component failure on PCB, Undersized or damaged supply cable

How to Fix / Troubleshooting

Safety first: Do not repeatedly reset a breaker that trips instantly; this may indicate a short circuit.

  • Check current settings: In the EO app or installer interface, confirm that the maximum charging current does not exceed the breaker and cable rating.
  • Inspect for visible damage: With power off, open the charger and look for burnt components, melted insulation, or signs of arcing.
  • Check cable condition: Inspect the supply cable from the consumer unit to the charger for damage or overheating.
  • Test with reduced current: If the breaker trips only at higher currents, temporarily reduce the current limit and monitor operation while arranging for a full inspection.
  • Professional fault‑finding: A qualified electrician should perform continuity and insulation tests to locate any short circuits and replace the faulty component or wiring.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Supply cable to EO charger
Check Price on Amazon