E05
EO Charging
Internal Overtemperature Protection Trip
EO charger displays E05 and refuses to start; often logged as an over‑temperature event.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked ventilation around EO charger, High ambient temperature exceeding rating, Failed internal temperature sensor on PCB, Loose or overheated power terminals
How to Fix / Troubleshooting
Safety first: Overheating can damage insulation and components. If you smell burning or see smoke, isolate power immediately and do not reuse the charger until inspected.
- Check ambient conditions: Ensure the EO charger is not installed in direct sunlight or in an enclosed, unventilated space. Measure ambient temperature; if it exceeds the unit's rated operating range, improve ventilation or shading.
- Inspect for obstructions: Make sure no objects are blocking any vents or cooling paths on or around the charger. Maintain the clearance distances specified in the EO installation manual.
- Examine internal connections: With power off and cover removed, inspect line, neutral, and contactor terminals for signs of overheating: darkened insulation, melted plastic, or discolored copper. Re‑torque loose terminals and replace any heat‑damaged components.
- Check temperature sensor: Locate the thermistor or temperature sensor on the main PCB or heat sink. Ensure it is firmly attached and not physically damaged. A sensor that has detached from the heat sink can cause false over‑temperature readings.
- Allow cool‑down and reset: Let the charger cool for at least 30–60 minutes with power off. Restore power and attempt a short charging session while monitoring temperature. If E05 recurs quickly under normal load, the temperature sensing circuit or PCB may need replacement.