Garo Display Module Failure

Charger powers on but display is blank or unreadable; LEDs may still function.

Advertisements

Possible Causes

Faulty LCD/OLED display panel, Loose ribbon cable between display and main board, Backlight failure, Water ingress at front panel

How to Fix / Troubleshooting

Safety first: Isolate power before removing the front cover.

  • Check via app: If possible, connect to the charger using the Garo app or web interface to confirm that it is otherwise operating.
  • Inspect display connections: Open the front cover and reseat the ribbon cable or connector between the display and the main or interface board.
  • Look for moisture: Check for condensation behind the front window. If present, dry the area and inspect seals.
  • Replace display: If the display remains blank or distorted, replace the display module with a Garo‑approved spare.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Display Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements