Display Module Failure
Charger powers on but display is blank or unreadable; LEDs may still function.
Advertisements
Possible Causes
Faulty LCD/OLED display panel, Loose ribbon cable between display and main board, Backlight failure, Water ingress at front panel
How to Fix / Troubleshooting
Safety first: Isolate power before removing the front cover.
- Check via app: If possible, connect to the charger using the Garo app or web interface to confirm that it is otherwise operating.
- Inspect display connections: Open the front cover and reseat the ribbon cable or connector between the display and the main or interface board.
- Look for moisture: Check for condensation behind the front window. If present, dry the area and inspect seals.
- Replace display: If the display remains blank or distorted, replace the display module with a Garo‑approved spare.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Display Module
Check Price on Amazon