E15
go-e
External Load Management / Modbus Control Fault
Charger shows E15; app may indicate load management or external control error.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect wiring to external energy meter or Modbus device, Wrong Modbus address or baud rate configuration, Broken RS-485 cable, Faulty load management interface on control board
How to Fix / Troubleshooting
Safety: De-energize control wiring circuits before modifying connections.
- Check wiring: Verify that A/B (or +/–) lines from the external meter or controller are correctly connected to the go-e RS-485 or control terminals, observing polarity.
- Verify settings: In the go-e app or web interface, confirm that the correct meter type, Modbus address, and communication parameters are configured.
- Test bus integrity: Use a Modbus tester or connect a known-good device to confirm that the external meter is responding. Replace damaged cables or terminations.
- Isolate the charger: Temporarily disable external load management in the settings. If the error clears and charging works, the issue is external to the charger.
- Inspect control board: If communication fails with known-good wiring and devices, the load management interface on the control board may be defective and require replacement.