E07
GoCable Contactor Welded or Contactor Feedback Fault

E07 appears on display; charger will not energize; sometimes after a power outage.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Main contactor contacts welded closed, Faulty contactor feedback auxiliary contact, Control board misreading contactor state, Surge damage from power event

How to Fix / Troubleshooting

Safety warning: A welded contactor can leave the output live even when the charger appears off. Always verify absence of voltage with a meter before touching output conductors.

  • Power down fully: Turn off the EVSE breaker and confirm the display is off.
  • Inspect main contactor: Open the GoCable housing and locate the main power contactor. Look for signs of overheating or melted plastic.
  • Check mechanical operation: With power OFF, manually actuate the contactor (if possible) or listen/feel for movement when a technician briefly energizes the coil. If it is stuck, it must be replaced.
  • Verify auxiliary feedback wiring: Ensure the small control wires on the contactor auxiliary contacts are secure.
  • Replace defective contactor: If welding or mechanical failure is suspected, replace the main power contactor with an identical rated part. This should be done by a licensed electrician.
  • If E07 persists after contactor replacement: The main control board feedback circuit may be faulty.