E17
Grizzl-E Output Relay / Contactor Feedback Mismatch

Charger LEDs show error; unit may start but then immediately stop when vehicle requests current

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect wiring of feedback contacts, Failed auxiliary contact on contactor, Loose feedback connector on control board, Control board feedback circuit failure

How to Fix / Troubleshooting

Safety: Turn OFF power before inspection.

  • Identify feedback wiring: Locate the auxiliary contacts on the contactor (if used) and trace their wires back to the control board.
  • Check terminations: Ensure all feedback wires are firmly attached and not broken.
  • Test auxiliary contact: With the contactor manually actuated (power OFF), verify continuity across the auxiliary contact using a multimeter.
  • Resolution: Replace the contactor if the auxiliary contact is defective. If the auxiliary contact is good, the feedback input on the main control board may be faulty.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Power Contactor Auxiliary Contact
Check Price on Amazon