E06
Hager
Internal Overtemperature Protection
Hager EV charger shows E06; charging stops or will not start. Often described as ‘temperature fault’ or ‘overtemperature’ in logs.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked ventilation openings on charger housing, Direct sunlight causing enclosure overheating, Faulty internal temperature sensor on main PCB, Loose or overheated power terminals inside charger
How to Fix / Troubleshooting
Safety first: Overheating can lead to fire risk. If the enclosure feels very hot or smells of burnt plastic, switch off power immediately at the breaker.
Steps to try:
- Allow cooling: Stop charging and let the charger cool for at least 30 minutes. Ensure the front cover is not obstructed by objects or vegetation.
- Check installation location: If the charger is installed in direct sun, consider adding shading or a canopy. High ambient temperatures can trigger E06.
- Reduce charging current: If your Hager model or app allows, set a lower maximum current (e.g. from 32 A down to 16–20 A) and test again.
- Inspect ventilation: Make sure any side or bottom vents are clear of dust, cobwebs, or debris. Do not drill extra holes in the enclosure.
- If E06 recurs quickly: An internal temperature sensor or power component may be failing. A qualified technician should open the unit, check terminal torque, inspect for discoloration, and test the temperature sensor. Replace the main control board or power module if necessary.