E08
Hyundai Line-to-Line or Line-to-Neutral Short / Internal Power Stage Fault

E08 appears and charging stops; often associated with tripping of the upstream breaker or RCD.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted power semiconductor (e.g., relay contacts or surge suppressor) on power board, Damaged MOV surge protector, Internal wiring short between line conductors, Burned trace on power board

How to Fix / Troubleshooting

Safety first: If the breaker or RCD trips repeatedly, do not reset it more than once. Turn off power and leave it off until the fault is identified.

  • Visual inspection: With power OFF and cover removed, inspect the power board for burn marks, cracked components, or a charred smell.
  • Check internal wiring: Ensure no wires are pinched between the housing and cover or touching sharp metal edges.
  • Do not attempt component‑level repair: Power semiconductors and MOVs require proper testing equipment.
  • Professional service: Have a qualified EVSE technician test the power stage and replace the entire power board assembly if a short is confirmed.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Power Board Assembly
Check Price on Amazon

We may earn a commission from links on this page.