E17
Jaguar Configuration Memory / EEPROM Corruption

Charger shows E17; app indicates ‘Configuration error’ or ‘Parameter checksum fault’.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Interrupted firmware update, Power loss during configuration write, Faulty EEPROM on control PCB, Incompatible configuration file loaded

How to Fix / Troubleshooting

Safety first: This is a control-level fault; electrical safety is usually unaffected but treat the unit as out of service until resolved.

  • Step 1 – Power cycle: Turn off the charger for 5 minutes, then restore power.
  • Step 2 – Factory reset: Using the Jaguar wallbox app or internal service button sequence, perform a factory reset of configuration (note: you will need to reconfigure settings afterward).
  • Step 3 – Reconfigure: Re-enter installation parameters (supply type, max current, CT settings, Wi‑Fi, etc.) according to the installation certificate.
  • Step 4 – Firmware reflash: If E17 persists, reload the latest firmware using the official Jaguar service tool or USB method.
  • Step 5 – PCB replacement: If configuration cannot be stored or read reliably, the control PCB’s memory is likely defective and must be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Jaguar Wallbox Control PCB (EEPROM/Flash Memory)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements