E06
JuiceBox
Main Contactor / Relay Welded or Open
Charger displays E06 relay or contactor fault; unit clicks repeatedly or not at all when starting a session.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Welded contacts in main power contactor, Open coil in main power relay, Loose control wiring from board to contactor, Faulty contactor driver on main control board
How to Fix / Troubleshooting
Safety first: Turn off the breaker and verify absence of voltage before touching internal components. Do not attempt to pry open a welded contactor while energized.
- Listen for relay operation: When starting a charge (with cover on), you should hear a distinct click. No click suggests an open coil or driver issue; rapid chattering suggests low control voltage or failing contactor.
- Inspect contactor (power OFF): Remove the cover and locate the main power contactor. Check for burn marks, melted housing, or discoloration. If present, replace the main power contactor.
- Check coil connections: Ensure the small-gauge control wires from the main control board to the contactor coil are firmly seated and not damaged.
- Manual continuity test (advanced): With power OFF and wires removed, measure coil resistance with a multimeter. An open circuit indicates a failed coil. Also check continuity across the main contacts; a welded contact will show continuity even with no coil power.
- Board driver check: If the contactor tests good but never energizes, the main control board relay driver may be faulty and require replacement by a technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Power Contactor