E11
KEBA Non-Volatile Memory / Configuration Fault

Charger shows E11; internal memory or configuration error, may revert to default settings

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted EEPROM/flash memory on main control board, Interrupted firmware update, Electrostatic or surge damage to memory IC, Incompatible configuration file loaded

How to Fix / Troubleshooting

Safety first: Configuration work is low-voltage, but opening the charger still requires isolating mains power.

Step-by-step checks:

  • 1. Power-cycle: Turn the charger off at the breaker for 60 seconds and then back on. Observe whether E11 reappears.
  • 2. Backup configuration: If possible, connect via KEBA's configuration tool or web interface and export the current configuration for backup.
  • 3. Restore defaults: Perform a factory reset according to KEBA documentation. Then re-enter essential settings (supply type, max current, authorization mode).
  • 4. Firmware update: Check KEBA's support site for the latest firmware. Apply updates carefully, ensuring power is stable and the process is not interrupted.
  • 5. Re-import configuration: If you have a known-good configuration file, import it and test operation.
  • 6. Replace main board: If E11 persists after reset and firmware update, the non-volatile memory on the main control board is likely defective and the board should be replaced.

Document all settings before performing resets to minimize downtime.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.