KEBA
Fan Control or Temperature Sensing Anomaly
KEBA charger’s internal fan runs loudly or continuously even at low charging currents
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty temperature sensor reading high, Fan control circuit stuck on, Blocked airflow causing real overheating, Fan bearings worn causing noise
How to Fix / Troubleshooting
Safety first: Isolate power before touching the fan or internal components.
Steps:
- 1. Check ambient conditions: Ensure the charger is not installed in a very hot or enclosed space.
- 2. Inspect vents: Clean any dust or debris from ventilation openings.
- 3. Internal inspection: Open the housing and check that the temperature sensor is properly attached to its mounting point (e.g., heat sink).
- 4. Replace fan: If the fan is mechanically noisy, replace the internal cooling fan.
- 5. Sensor/board replacement: If the fan runs at full speed despite normal temperatures, replace the temperature sensor or main control board as required.
Continuous fan operation may be a protective response; verify actual temperatures before assuming a fault.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Internal Cooling Fan
Check Price on Amazon
We may earn a commission from links on this page.