Lectron Moisture Ingress / Compromised Weather Sealing

Lectron charger installed outdoors shows signs of water inside the enclosure or condensation on the inside of the front cover.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged enclosure gasket, Loose cover screws, Improperly sealed cable glands, Mounting orientation allowing water entry

How to Fix / Troubleshooting

Safety first: Turn OFF the breaker and allow the unit to dry before further use. Water inside an EVSE is hazardous.

  • 1. Dry the interior: With power OFF and cover removed, gently dry internal surfaces with a lint-free cloth and allow the unit to air dry for at least 24 hours in a dry environment.
  • 2. Inspect seals and gaskets: Check the perimeter gasket on the Lectron cover for cracks or compression set. Replace if damaged.
  • 3. Tighten cable glands: Ensure all cable entries are properly compressed around the cable jacket and that no gaps are visible.
  • 4. Verify mounting: Confirm the unit is mounted vertically as specified by Lectron, with drip loops on cables where recommended.

Resolution: If corrosion or damage is visible on the main control board or wiring, replace affected components or the entire EVSE. Improve weatherproofing or relocate the charger to prevent recurrence.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Lectron Enclosure Gasket / Cable Glands