Lectron Keypad / Button Input Failure

Lectron charger’s front panel buttons (if equipped) do not respond or respond intermittently, but the display is on.

Advertisements

Possible Causes

Failed membrane keypad on display board, Loose keypad ribbon cable, Contamination or moisture under buttons

How to Fix / Troubleshooting

Safety first: Turn OFF the breaker before removing the front panel.

  • 1. Power reset: Turn OFF the breaker for a few minutes, then ON, to rule out a software freeze.
  • 2. Inspect keypad cable: With power OFF, open the unit and reseat the keypad ribbon or harness on the display board.
  • 3. Check for moisture: Look for condensation or liquid ingress around the front panel. Dry thoroughly and improve sealing if needed.

Resolution: If buttons remain unresponsive, replace the Lectron display/keypad assembly.