E07
Lucid Overtemperature Protection (Internal Overheat)

Lucid charger shows E07 and fan runs at high speed or cycles; charging stops or will not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked ventilation openings on Lucid wall unit, Failed internal cooling fan, Degraded thermal interface or sensor on power module

How to Fix / Troubleshooting

Safety first: Turn OFF power before cleaning vents or opening the unit.

Steps:

  • Check installation clearance: Ensure the Lucid charger has the minimum side/top/bottom clearances specified in the manual. Remove any stored items blocking airflow.
  • Clean vents: Use a vacuum with a brush attachment to gently remove dust from intake and exhaust grilles.
  • Ambient temperature: If installed in a hot garage, try charging during cooler hours. High ambient temperature can trigger E07.
  • Listen for fan: During startup, you should hear the internal Lucid cooling fan. If silent, the fan may have failed.

Technician actions:

  • With cover removed and power OFF, spin the fan blades by hand to check for binding.
  • Verify fan connector is seated on the Lucid control or power board.
  • Replace the Lucid cooling fan assembly if inoperative, and inspect thermal sensors on the power module.

Resolution: After restoring airflow or replacing the fan, clear the error by power-cycling and monitor temperature readings if available in the Lucid app.