E08
Lucid Protective Earth (Ground) Fault / Missing Ground

Display shows E08; charger will not start and may indicate ‘Ground Missing’ or ‘Protective Earth Fault’.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open ground conductor in supply wiring, Loose ground lug inside Lucid charger, Corroded or improperly bonded ground at service panel

How to Fix / Troubleshooting

Safety first: Do not operate the charger without a verified equipment ground. Turn OFF the breaker.

Steps:

  • Check ground conductor: At the Lucid charger input, verify the green or bare ground wire is present and firmly secured to the ground terminal.
  • Inspect ground lug: Ensure the internal ground bus or lug in the Lucid unit is tight and free of corrosion.
  • Panel inspection (electrician): Have a licensed electrician verify that the branch circuit ground is continuous back to the service panel and properly bonded.

Resolution: Once a solid ground path is restored and all terminations are tightened to spec, power-cycle the Lucid charger. If E08 persists, the internal ground monitoring circuit on the control board may be faulty and require replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Lucid Ground Terminal / Control Board Ground Monitor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements