E11
Lucid Configuration / DIP Switch / Current Setting Error

Lucid charger shows E11 and refuses to start; often after configuration changes or installation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect maximum current setting on Lucid control board, Mismatched configuration between app and internal DIP switches, Corrupted configuration memory

How to Fix / Troubleshooting

Safety first: Turn OFF power before accessing internal settings.

Steps:

  • Verify current setting: Open the Lucid charger and locate the current-setting DIP switches or rotary selector on the control board. Confirm they match the branch circuit rating and installation manual.
  • Check app settings: In the Lucid charger app, ensure the maximum current does not exceed the hardware setting or breaker rating.
  • Reset to defaults: If available, perform a factory reset from the front panel or app, then reconfigure step-by-step.

Resolution: After correcting settings, power-cycle the charger. If E11 persists, the configuration memory or microcontroller on the control board may be faulty and require board replacement.