E19
Lucid Pilot Duty Cycle / Current Encoding Error

Lucid charger shows E19; vehicle reports ‘Pilot Error – Incompatible EVSE’.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty PWM generator on Lucid control board, Incorrect resistor network on pilot circuit, Short between pilot and ground in cable

How to Fix / Troubleshooting

Safety first: Turn OFF power before opening the unit or handling the cable.

Steps:

  • Inspect cable: Look for damage near the handle where pilot wiring is concentrated.
  • Test with another EV: Confirm the issue is not vehicle-specific.
  • Internal inspection (technician): Check the pilot terminal connections on the Lucid control board and verify no stray strands or shorts to ground.

Resolution: If no cable fault is found, replace the Lucid control board (which contains the pilot PWM generator and encoding resistors) or the entire output cable if pilot conductor is compromised.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Lucid Control Board (Pilot Circuit) / Output Cable
Check Price on Amazon