E13
Mennekes Load Management / External Control Fault

Charger shows E13; charging current is limited or session aborted due to load management error.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loss of communication with external load controller, Incorrect configuration of load management mode, Faulty Modbus or Ethernet interface, Broken communication cable

How to Fix / Troubleshooting

Safety first: De-energize before working on communication wiring.

  • Check configuration: In the Mennekes configuration menu or software, verify whether external load management is enabled. If no external controller is present, disable this mode.
  • Inspect communication cabling: For Modbus/RS-485 or Ethernet-based control, check that cables are intact, correctly terminated, and firmly connected.
  • Test standalone mode: Temporarily configure the charger to standalone operation (no external load control) and see if charging works normally.
  • Interface module: If the error persists, the communication interface module or section of the main PCB may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Load Management / Communication Interface Module
Check Price on Amazon