E15
Mini
Isolation Monitoring Device (IMD) Fault
Charger shows E15; internal self-test fails at startup; no charging allowed
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective internal isolation monitoring module, Moisture or contamination on high-voltage components, Wiring error between IMD and main PCB, Degraded insulation in power module
How to Fix / Troubleshooting
Danger: Isolation faults can lead to electric shock. Do not bypass IMD.
- Power down and inspect (technician): With power OFF and cover removed, inspect the power module, DC bus, and IMD connections for moisture, dust, or contamination. Clean with dry compressed air if needed.
- Check IMD wiring: Ensure all connectors between the IMD and main PCB are secure and correctly oriented.
- Drying period: If moisture is suspected (e.g., condensation), allow the charger to dry in a warm, dry environment for 24 hours before retesting.
- Replace IMD module: If E15 persists and no external cause is found, replace the isolation monitoring device with a Mini-approved part.
After replacement, run the built-in self-test to confirm proper operation.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Mini EV Charger Isolation Monitoring Device
Check Price on Amazon