E008
myenergi
Phase Configuration / Phase Loss Error
Zappi displays E008, will not charge, often after wiring changes or new installation
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect phase wiring on 3-phase Zappi, One phase missing or not connected, Loose phase terminal, Faulty phase detection circuit
How to Fix / Troubleshooting
Safety first: Only a qualified electrician should work on 3‑phase wiring.
- 1. Confirm model type: Verify whether your Zappi is single-phase or three-phase and that the installation matches the model.
- 2. Check supply phases: With power isolated, open the Zappi and confirm that all required L1, L2, L3, N, and Earth conductors are correctly landed and tightened.
- 3. Verify at consumer unit: Ensure the 3‑pole MCB/RCBO feeding the Zappi is on three live phases and that none of the poles are off or tripped.
- 4. Measure phase voltages: An electrician should measure L1–N, L2–N, L3–N and between phases to confirm all are present and within tolerance.
- 5. Configuration check: In the Zappi menu, verify that the phase configuration is set correctly (single vs three-phase). Incorrect settings can trigger E008.
- 6. If wiring and configuration are correct: The internal phase detection circuitry on the main PCB may be faulty and require board replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Phase Detection Circuit (Main PCB)
Check Price on Amazon
We may earn a commission from links on this page.