E011
myenergi
PEN Conductor Fault Detected
Zappi displays E011, charging disabled, often associated with PEN/earth monitoring on TN-C-S supplies
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Detected rise in earth potential, Broken neutral in supply network, Incorrect PEN monitoring configuration, Faulty PEN detection circuit
How to Fix / Troubleshooting
Critical safety warning: A PEN fault can make all earthed metalwork live. Do not bypass this protection.
- 1. Stop using the charger: Do not attempt to charge until the supply has been checked by a qualified electrician.
- 2. Verify supply type: Confirm with your installer and documentation whether your installation is TN‑C‑S, TN‑S, or TT, and ensure the Zappi is configured accordingly.
- 3. Electrical inspection: Have an electrician test for neutral integrity and earth potential rise at the property. Any supply-side PEN issues must be reported to the DNO/utility.
- 4. Check bonding: Confirm main protective bonding to gas, water, and structural steel is intact and correctly sized.
- 5. Reset and retest: After any supply-side repairs, power-cycle the Zappi and test. If E011 persists with a verified-good supply, the internal PEN detection module may be faulty.
- 6. Do not defeat PEN protection: Never link neutral and earth or alter internal wiring to clear the error. Replace the faulty detection circuit or main PCB instead.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
PEN Fault Detection Module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements