E012
myenergi
Relay / Contactor Feedback Fault
Zappi shows E012, charging stops, often when switching between ECO and FAST modes
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or welded main contactor, Faulty contactor feedback microswitch, Relay driver failure on PCB, Mechanical obstruction in contactor
How to Fix / Troubleshooting
Safety first: A welded contactor can leave the output live even when the charger reports off. Isolate power before inspection.
- 1. Listen for contactor operation: When starting/stopping a charge, you should hear a distinct click from inside the Zappi. No click or continuous humming suggests contactor issues.
- 2. Power off and inspect: Isolate the supply and remove the cover. Locate the main power contactor and check for signs of overheating or melting.
- 3. Check feedback wiring: Some models use auxiliary contacts or feedback wires from the contactor to the PCB. Ensure these are securely connected.
- 4. Mechanical test (power off): Gently operate the contactor manually if possible (per manufacturer guidance) to see if it moves freely.
- 5. Replace contactor if suspect: If the contactor shows signs of damage or sticking, replace it with the exact myenergi-specified part and torque terminals correctly.
- 6. If new contactor does not resolve: The relay driver or feedback circuit on the main PCB may be faulty and require board replacement.