E014
myenergi Grid Reference / Phase Rotation Error

Zappi shows E014, charging disabled, often after CT or grid configuration changes

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect CT placement on phases, Wrong phase rotation on 3‑phase system, Misconfigured grid reference CT, Faulty phase/CT correlation on PCB

How to Fix / Troubleshooting

Safety first: Phase rotation issues affect all 3‑phase loads; only qualified electricians should alter phase wiring.

  • 1. Verify CT placement: Ensure each CT clamp is on the correct phase conductor and that the Zappi CT configuration matches the physical installation.
  • 2. Check phase rotation: An electrician should verify L1‑L2‑L3 rotation at the supply and at the Zappi. Correct any swapped phases.
  • 3. Re-run setup: Use the Zappi’s advanced menu to re-run any grid/CT setup wizards so it can learn the correct phase relationships.
  • 4. Inspect CT wiring: Confirm that CT1, CT2, CT3 leads are not crossed or extended incorrectly.
  • 5. Test in FAST mode: Temporarily switch to FAST mode (ignoring CTs) to see if the charger operates normally. If so, the issue is limited to CT/phase sensing.
  • 6. Persistent E014 with correct wiring: Suggests a fault in the phase/CT correlation logic on the main PCB, requiring board replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Grid CT Clamp
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements