E014
myenergi
Grid Reference / Phase Rotation Error
Zappi shows E014, charging disabled, often after CT or grid configuration changes
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect CT placement on phases, Wrong phase rotation on 3‑phase system, Misconfigured grid reference CT, Faulty phase/CT correlation on PCB
How to Fix / Troubleshooting
Safety first: Phase rotation issues affect all 3‑phase loads; only qualified electricians should alter phase wiring.
- 1. Verify CT placement: Ensure each CT clamp is on the correct phase conductor and that the Zappi CT configuration matches the physical installation.
- 2. Check phase rotation: An electrician should verify L1‑L2‑L3 rotation at the supply and at the Zappi. Correct any swapped phases.
- 3. Re-run setup: Use the Zappi’s advanced menu to re-run any grid/CT setup wizards so it can learn the correct phase relationships.
- 4. Inspect CT wiring: Confirm that CT1, CT2, CT3 leads are not crossed or extended incorrectly.
- 5. Test in FAST mode: Temporarily switch to FAST mode (ignoring CTs) to see if the charger operates normally. If so, the issue is limited to CT/phase sensing.
- 6. Persistent E014 with correct wiring: Suggests a fault in the phase/CT correlation logic on the main PCB, requiring board replacement.
Advertisements
Repair Difficulty
Hard